Kevlar Braided Rubber Power & Control
Ship Loaders & Cranes

0.6/1kV 90°C
Si
m
ze
Min. Bend
Radius mm
Nom. Cond.
OD mm
Nom. Cable
OD mm
Current Rating
amp
Current Rating
amp
Approx. Wt.
kg/km
3C 1.5 40 1.6 13.5 25 23 190
3C 2.5 44 2.1 14.7 33 30 242
3C 4 47 2.6 15.8 44 40 304
3C 6 52 3.2 17.2 56 51 388
3C 10 57 4.0 19.0 79 72 530
3C 16 65 5.2 21.8 106 96 768
3C 25 76 6.3 25.3 141 128 1074
3C 35 84 7.4 27.8 174 158 1407
3C 50 96 8.9 31.9 219 199 1924
4C 1.5 43 1.6 14.4 21 19 221
4C 2.5 47 2.1 15.7 29 26 286
4C 4 51 2.6 17.0 37 34 365
4C 6 56 3.2 18.5 47 43 472
4C 10 62 4.0 20.6 67 61 655
4C 16 71 5.2 23.7 89 81 961
4C 25 83 6.3 27.6 119 108 1353
4C 35 91 7.4 30.5 149 135 1785
4C 50 106 8.9 35.4 187 170 2476
4C 70 125 11.0 41.5 235 214 3545
4C 95 136 12.5 45.3 282 256 4356
4C 120 156 14.7 52.0 333 303 5893
4C 150 173 16.3 57.5 383 348 7224
4C 185 191 18.2 63.6 436 396 8824
5C 1.5 46 1.6 15.2 21 19 253
5C 2.5 50 2.1 16.7 29 26 332
5C 4 54 2.6 18.1 37 34 429
5C 6 60 3.2 19.9 47 43 559
5C 10 67 4.0 22.2 67 61 784
5C 16 77 5.2 25.6 89 81 1160
5C 25 90 6.3 30.0 119 108 1642
5C 35 100 7.4 33.4 149 135 2190
5C 50 117 8.9 38.9 187 170 3050
5C 70 137 11.0 45.7 235 214 4375
5C 95 150 12.5 49.9 282 256 5381
5C 120 172 14.7 57.4 333 303 7288
5C 150 191 16.3 63.5 383 348 8939
7C 1.5 49 1.6 16.2 299
7C 2.5 53 2.1 17.8 401
12C 1.5 60 1.6 19.9 467
12C 2.5 66 2.1 22.1 642
18C 1.5 68 1.6 22.6 627
18C 2.5 76 2.1 25.3 878
25C 1.5 77 1.6 25.8 824
25C 2.5 87 2.1 29.0 1165

Continuous current carrying capacities are calculated assuming 40° ambient temperature in free air, flexible unenclosed touching. For other installation methods, please refer to our current ratings table.

Conductor Comparison - TriCab versus Class 5 & 6 (approximate no.of wires)
Size mm²50 70 95 120 150 185 240 300 400 500 630
TriCab658 969 1216 1672 2052 2508 3256 4144 5368 6832 8784
Class5378 342 465 587 734 905 1174 1468 1958 1710 2155
Class6662 927 1258 1589 1987 1401 1817 2272
Issue 19.0