IX Shipboard & Offshore
Switchboard/Panel Wire
O² >32. HCL >0.5%
Typical Applications
Flexible Single Insulated Power Cables suitable for all shipboard and marine applications.
Flexible finely stranded conductor for easy routing in tight switchboard layouts
Low Smoke Zero Halogen (LSZH) insulation for enhanced fire safety
Splash resistant to oil, skydrol, petrol, acid, and seawater
UV and ozone resistant – ideal for harsh outdoor or marine environments
Wide operating temperature: -40°C to +110°C
Construction
Conductor
Fine wire plain or tinned annealed copper to IEC 60228 and AS/NZS 1125.
Insulation
'Easy Strip' LSZH/XLPO HF-90 to IEC 60092-360
Operating Temp
-40°C to +90°C
(Tested to 110°C)
Voltage Rating
600/1000 Volts
Compliance
Certifications
Standards
IEC 60228
IEC 60092-350
IEC 60092-353
IEC 60332-1
IEC 60332-3-22
Cat A
IEC 60754-1&2
IEC 61034-1&2
IEEE 45
IEEE 1580
IEEE 1202
AS/NZS 1125
m |
ze m² |
Min. Bend Radius mm |
Nom. Cond. OD mm |
Nom. Cable OD mm |
Current Rating amp |
Approx. Wt. kg/km |
|---|
IEC 60092-352:2005 Table B.4 - Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature.
| Conductor Comparison - TriCab versus Class 5 & 6 (approximate no.of wires) |
| Size mm² | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| TriCab | 658 | 969 | 1216 | 1672 | 2052 | 2508 | 3256 | 4144 | 5368 | 6832 | 8784 |
| Class5 | 378 | 342 | 465 | 587 | 734 | 905 | 1174 | 1468 | 1958 | 1710 | 2155 |
| Class6 | 662 | 927 | 1258 | 1589 | 1987 | 1401 | 1817 | 2272 |