USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC
Size awg/kcmil |
Min. Bend Radius inch |
Nom. Cond. OD inch |
Nom. Cable OD inch |
Current Rating amp |
Approx. Wt. lb/kft |
| 18 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
0.3 |
0.05 |
0.12 |
20 |
10 |
| Please contact your rep |
|
| 16 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
0.4 |
0.06 |
0.13 |
25 |
15 |
| Please contact your rep |
|
| 14 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
0.4 |
0.08 |
0.14 |
35 |
20 |
| Please contact your rep |
|
| 12 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
0.5 |
0.10 |
0.16 |
45 |
30 |
| Please contact your rep |
|
| 10 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
0.6 |
0.12 |
0.19 |
60 |
45 |
| Please contact your rep |
|
| 8 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
0.8 |
0.16 |
0.26 |
80 |
80 |
| Please contact your rep |
|
| 6 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
1.0 |
0.20 |
0.33 |
120 |
120 |
| Please contact your rep |
|
| 4 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
1.1 |
0.25 |
0.38 |
160 |
170 |
| Please contact your rep |
|
| 2 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
1.3 |
0.32 |
0.44 |
210 |
250 |
| Please contact your rep |
|
| 1 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
1.6 |
0.35 |
0.52 |
245 |
330 |
| Please contact your rep |
|
| 1/0 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
1.7 |
0.39 |
0.56 |
285 |
400 |
| Please contact your rep |
|
| 2/0 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
1.9 |
0.45 |
0.62 |
330 |
500 |
| Please contact your rep |
|
| 3/0 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
2.0 |
0.50 |
0.67 |
385 |
620 |
| Please contact your rep |
|
| 4/0 |
|
[[""]] |
USE PL#403 BOAT OR MTW(105Â Deg./75Â Deg.C WET/DRY)OR1 FT-2 ROHS ABYC |
2.2 |
0.57 |
0.74 |
445 |
750 |
| Please contact your rep |
|
Current Rating based on ABYC E-11 Table VI. Single Conductor in Air, Cond. Temp 105°C, Ambient Temp 30°C, Outside Engine Spaces
There is a +5% tolerance to the NOMINAL values due to manufacturing process variations. TriCab is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time.
Issue 19.0