EU

Flexible LSZH Rubber
Coll. Scr. & braid VSD/VFD

0.6/1kV 125°C
Insulation X-HF-110
EU_CU

Typical Applications

Suitable for fixed wiring application where EMC protection is required.

Standard Core Configuration

Other Colours available on request

Construction

Conductor Fine wire plain or tinned annealed copper to IEC 60228 and AS/NZS 1125.

Insulation LSFLEX® XL-125 (X-10), Cross-Linked,Thermoset, Elastomeric, Low Smoke Zero Halogen. 125°C max operating temperature conforms to UL1581.

Separator Polypropylene tape

Screen Copper Laminate tape

Braid Tinned Copper Wire braid(90%)

Separator Polypropylene tape

Jacket LSFLEX® T-10 (HFS-110-TP), Flame Retardant, Cross Linked, Thermoset, Elastomeric, Low Smoke Halogen. Splash resistant to oil, skydrol, petrol, acid and sea water. Resists ozone and UV. Excellent abrasion resistance. Anti-Termite/Rodent Jacket is available.

Operating Temperature

  • -40°C to 125°C

Voltage Rating

  • 600/1000Volts

Core Identification

  • To customer specification

Jacket Colour

  • To customer specification

Standards

  • AS/NZS 1125
  • AS/NZS 1660.5.1
  • AS/NZS 1660.5.2
  • AS/NZS 1660.5.4
  • AS/NZS 1660.5.6
  • AS/NZS 3008.1
  • AS/NZS 3008
  • AS/NZS 5000.1
  • IEC 60228
  • IEC 60332-1
  • IEC 60332-3-22
  • IEC 60754-2
  • IEC 61034-1&2

 

Si
m
ze
Ea
m
rth
Min. Bend
Radius mm
Nom. Cond.
OD mm
Nom. Ins.
OD mm
Nom. Braid
OD mm
Nom. Cable
OD mm
Current Rating
amp
Current Rating
amp
Approx. Wt.
kg/km
1c 6 36.3 3.0 4.4 6.0 9.1 61 57 139
1c 10 40.2 4.0 5.4 7.0 10.1 86 80 188
1c 16 44.3 5.0 6.4 8.0 11.1 112 105 251
1c 25 50.2 6.2 8.1 9.7 12.6 149 139 347
1c 35 55.7 7.4 9.2 10.8 13.9 184 172 453
1c 50 62.4 8.8 10.8 12.4 15.6 232 217 602
1c 70 71.4 10.6 12.8 14.4 17.9 292 273 838
1c 95 79.2 12.3 14.5 16.1 19.8 352 329 1028
1c 120 89.0 14.5 17.0 18.6 22.2 417 390 1356
1c 150 98.8 16.3 19.2 20.8 24.7 482 450 1697
1c 185 108.2 18.0 21.3 22.9 27.1 552 516 2041
1c 240 119.3 20.3 23.8 25.4 29.8 663 620 2579
1c 300 129.9 22.5 26.2 27.8 32.5 764 714 3216
1c 400 146.7 26.0 30.1 31.7 36.7 915 855 4094
1c 500 162.2 29.2 33.7 35.3 40.5 1059 990 5118
1c 630 180.2 32.8 37.7 39.3 45.0 1235 1154 6391
3c 1.5 1c 1.5 52.6 1.5 8.6 13.2 26 24 226
3c 2.5 1c 2.5 57.1 1.9 9.7 14.0 34 32 282
3c 4 1c 4 62.0 2.5 10.9 15.5 45 42 356
3c 6 1c 6 67.3 3.0 12.3 16.8 58 54 451
3c 10 3c 1.5 73.8 4.0 13.8 18.5 80 75 549
3c 16 3c 2.5 77.5 5.0 15.3 19.4 106 99 741
3c 25 3c 4 91.4 6.2 18.8 22.8 140 131 1073
3c 35 3c 6 101.2 7.4 21.1 25.3 173 162 1417
3c 50 3c 10 115.5 8.8 24.4 28.9 218 204 1978
3c 70 3c 10 133.8 10.6 28.7 33.5 273 255 2669
3c 95 3c 16 149.3 12.3 31.9 37.3 327 306 3366
3c 120 3c 16 166.5 13.9 35.7 41.6 385 360 4148
3c 150 3c 25 180.7 15.1 39.0 45.2 442 413 5208
3c 185 3c 25 200.7 16.9 43.7 50.2 503 470 5965
3c 240 3c 35 221.5 18.9 48.4 55.4 598 559 7800
3c 300 3c 50 247.2 21.5 54.3 61.8 683 638 9962

Continuous current carrying capacities are calculated assuming 40° ambient temperature in free air, flexible unenclosed touching. For other installation methods, please refer to our current ratings table.

Conductor Comparison - TriCab versus Class 5 & 6 (approximate no.of wires)
Size mm²50 70 95 120 150 185 240 300 400 500 630
TriCab658 969 1216 1672 2052 2508 3256 4144 5368 6832 8784
Class5378 342 465 587 734 905 1174 1468 1958 1710 2155
Class6662 927 1258 1589 1987 1401 1817 2272